3KGROUP TECHNOLOGY BLOG RUCKUS EDGECORE PLUME

The R320 AP standalone software needs to be upgraded to 114.x before connecting to the virtual SmartZone 5.2 zone.
The R320 AP standalone software needs to be upgraded to 114.x before connecting to the virtual SmartZone 5.2 zone.
  sildid: -
  23/03/2020

Ruckus AP R320 has a bug that with standalone soft 112.0.0.0.920 (and probably the rest of the 112.x softwares) it can't properly connect to virtual SmartZone 5.2.0.0.699 and bricks. Similar case applies to 5.2.0.0.685. For 5.2.0.0.685 the solution is to connect the AP first to the vSZ 5.1 zone and only after the firmware update it can be upgraded to 5.2. This solution can also be used with 5.2.0.0.699, but there's another way also: update the standalone software to 114.x (we tested 114.0.0.0.1360 specifically as with the latest available at that time) and then it's safe to connect to SZ 5.2.

We have upgraded our AP-s in stock to 114.x standalones today, in near future the the manufacturing process will also catch up.